Hi Greg,is there any reason why not just use a Maxwell Cap with these specs? By the way, 3 years ago I have built a similar DC resonant charging system (still without primary / secondary coils, but charging system works very well...). Have a look at my video:
https://www.youtube.com/watch?v=w5-x84V9Pqk Regards, Stefan Am 10.10.2018 um 11:54 schrieb Greg Peters:
Hi All, I’m working on a large 3-phase DC resonant charged magnifier coil and would like to attempt to order a custom capacitor to enable a small, neat and compact design. The coil is going to run at about 15kVA with the primary cap charged to near 18kV at 500BPS. I expect Fres to be between 75 and 100kHz, so peak primary currents of perhaps 2000 to 3000 amps. I was thinking I would specify a 40kV DC and 5000 amp peak rating – how does that sound? Now, is anyone able to offer some advice regarding the specs I should request for things like: RMS current, DV/DT ESL ESR Ripple Voltage (assume 100%???) Etc Any advice would be greatly appreciated! Regards, Greg Sent from Mail for Windows 10 _______________________________________________ Tesla mailing list Tesla@xxxxxxxxxxxxxxxxxx https://www.pupman.com/mailman/listinfo/tesla