[Home][2018 Index]
Run the motor on a different circuit. 1/2 horse is kind of overkill to spin a little disk. I think my SRSG is only 1/8 hp. Also, at what variac setting does it blow the fuse / breaker? On Sun, Nov 18, 2018 at 9:54 PM Daniel Kunkel <dankunkel@xxxxxxxxx> wrote: > I finally got my SRSG online tonight. To my dismay I started blowing 30 amp > fuses in my supply variac. I am hoping the list can help me figure out why > this is happening...we have guests coming over for Thanksgiving and they > are expecting a show!!! LOL > > When I was running the previous setup using a vacuum quenched single gap, > my NST bank (15kv @ 120ma) was only pulling 10 amps using a total of 302 uF > in PFC caps. I was expecting similar performance with the rotary gap. > > Basic specs are: > 6.5 x 26.5" secondary with 1,057 turns or 22 awg > .033uF MMC > 1.8 kva NST's > Terry Filter > 1/2 HP, 3,600 RPM motor > 2 flying electrodes (1/8" tungsten, through disc design), for 120 BPS > > Thanks for any insight, > ~Dan > Kansas City area > _______________________________________________ > Tesla mailing list > Tesla@xxxxxxxxxxxxxxxxxx > https://www.pupman.com/mailman/listinfo/tesla > _______________________________________________ Tesla mailing list Tesla@xxxxxxxxxxxxxxxxxx https://www.pupman.com/mailman/listinfo/tesla