[Home][2018 Index] [TCML] Measuring "Energy Discharge Capacitor Information" [Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[TCML] Measuring "Energy Discharge Capacitor Information"



On 6/18/18 7:51 AM, Bert Hickman wrote:
Hi Chris,

These are also heavy-duty energy discharge caps, using a kraft paper-foil dielectric system. The Aerovox PM series are all rated at 20% voltage reversal, and no self-healing.

The low capacitance and dielectric system for your caps limit their use to low pulse-rate, very high-voltage applications, such as flash X-ray, Marx generators, exploding wire, or rock fragmentation work. The dielectric system will be fairly lossy for lower-voltage oscillatory applications, and the stored energy is limited for coin shrinking since work-coil flashover limits maximum cap voltage to 20-25 kV.


Kind of drifting from TC, but I shrink quarters to dime sized at 20kV.



You might be able to get more information by directly contacting the folks at Aerovox. Unfortunately, many of their energy discharge caps are custom designs. This often binds Aerovox to non-disclosure agreements with their customers, preventing them from releasing even basic capacitor specs...



More TC related.. maybe some discussion about "how to measure" capacitor properties might be interesting.

You're not going to be able to get #of shot life kind of data, but maybe you could measure losses.

These days, an Arduino, Beagle, or Rpi might be enough data acquisition capability to measure a lot of useful component and assembly parameters.

It's been a while since Terry Fritz was making Q measurements with a digital oscilloscope.




Best wishes,

Bert


_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxxxxxxxxxx
https://www.pupman.com/mailman/listinfo/tesla