[Home][2015 Index] Re: [TCML] Inrush Current Limiting [Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TCML] Inrush Current Limiting



This circuit is also known as a "step-start" circuit.

On Friday, January 2, 2015, Clive Penfold <clivepenfold@xxxxxxxxxxxxxx>
wrote:

> The simplest circuit that I have seen to limit the inrush current into a
> highly inductive low resistance load is merely a mains relay or contactor
> and a low value resistor.
> The relay is after the on switch, straight across the mains, and when it
> pulls in, it shorts out the resistor which is in series with the load.
> The short time it takes for the relay to operate is enough for the
> magnetic field to become established.
> Regards,
> Clive
> _______________________________________________
> Tesla mailing list
> Tesla@xxxxxxxxxx <javascript:;>
> http://www.pupman.com/mailman/listinfo/tesla
>


-- 
Dave Sharpe, TCBOR/HEAS
Chesterfield, VA USA

Sharpe's Axiom of Murphy's Law
"Physics trumps opinion!"