[Home][2014 Index]
Agree. Ed Ronald Reeland wrote:
Carl and Jim: Recheck your math computations. I believe the Transformer impedance is 500,000 ohms or .5 meg-ohms. Then the inductance is 1326 henrys or 1.326 kilo-henry. Ron_______________________________________________From: cn8@xxxxxxx To: tesla@xxxxxxxxxx Date: Sun, 2 Feb 2014 13:43:20 -0700 Subject: Re: [TCML] NST model That's a big honkin' inductance, but it makes sense. I'll try it. Thanks--- Carl-----Original Message----- From: Jim Lux Sent: Saturday, February 01, 2014 2:24 PM To: Tesla Coil Mailing List Subject: [TCML] NST model The shunt results in large leakage inductance. Model it as a very large inductor in series with the secondary.For instance, if you have a 15kV, 30mA transformer, that implies that the series impedance of the secondary is 15E3/30E-3 or 5 Megohms. Using X = L *2*pi*f At 60 Hz, that's 13kHenry_______________________________________________ Tesla mailing list Tesla@xxxxxxxxxx http://www.pupman.com/mailman/listinfo/tesla _______________________________________________ Tesla mailing list Tesla@xxxxxxxxxx http://www.pupman.com/mailman/listinfo/teslaTesla mailing list Tesla@xxxxxxxxxx http://www.pupman.com/mailman/listinfo/tesla
_______________________________________________ Tesla mailing list Tesla@xxxxxxxxxx http://www.pupman.com/mailman/listinfo/tesla