[Home][2014 Index] Re: [TCML] Tesla coil threat to pacemakers [Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TCML] Tesla coil threat to pacemakers



Volts per meter in air is nothing if you are a 6 foot tall 50 ohm resistor. Resistance makes it futile.
(until the lightning bolt actually hits).

Peter
tesladownunder.com


--------------------------------------------------
From: "Carl" <cn8@xxxxxxx>
Sent: Monday, April 21, 2014 10:42 PM
To: "Tesla Coil Mailing List" <tesla@xxxxxxxxxx>
Subject: Re: [TCML] Tesla coil threat to pacemakers

15 kV/m is an electric field of 15,000 volts per meter. If you are outside in a strong thunderstorm, the electric field due to charges in the cloud can get as high as 15 kV/m or even higher. If the field is this high, lightning may be imminent. If you have a Tesla coil generating 500,000 volts, the field in its immediate vicinity could be 250,000 V/m. Walking across a carpet on a winter day can generate fields in the vicinity of 1 kV/m or 1,000 V/m.



_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla