[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
RE: [TCML] Primary connected to secondary
Hello Mark,
This seems to have gone unanswered, so I guess most of us havn't used PT's
much.
Is your circuit basically like this:
http://www.flickr.com/photos/33962508@N03/9724545221/
In other words the big brass nuts in your photos are the HV output, and you
have access, or a terminal, that connects to the cores?
Phil
-----Original Message-----
From: tesla-bounces@xxxxxxxxxx [mailto:tesla-bounces@xxxxxxxxxx] On Behalf
Of Mark X2
Sent: Sunday, September 08, 2013 4:12 PM
To: Tesla Coil Mailing List
Subject: [TCML] Primary connected to secondary
Hi all,
I'm upgrading my coil's power supply and intend to use 2x 20kV PT's with
parallel secondaries.
http://www.flickr.com/photos/91748036@N06/9638524069/
http://youtu.be/r_61XJ6AqZ4
Since they are single pole, one end of the HV winding is connected to the
laminated core, which needs to be connected to HF-ground. This also means
the primary circuit has a direct connection to the secondary.
Before, I used double pole PT's and was very comfortable with having a
floating primary circuit, not connected to the secondary. Do I need to take
additional or other precautions in this new setup?
Regards,
Mark
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla