[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Parallel NSTs was: Re: [TCML] Re: Tesla Digest, Vol 59, Issue 13
Although series wiring of NST secondaries is possible in principle, parallel is definitely the way to go for several reasons. Here are three:
1) Insulation in an NST is minimal even for its rated voltage; expect much internal arcing.
2) Corona problems scale exponentially with voltage and this dissipates power that should go to the Tesla Coil secondary.
3) Your wiring insulation and capacitor bank would have to be rated for twice the voltage--> $$$$.
Matt D.
-----Original Message-----
From: Nathan Woodhull <nwoodhull1@xxxxxxxxx>
To: tesla <tesla@xxxxxxxxxx>
Sent: Mon, Sep 17, 2012 6:47 am
Subject: [TCML] Re: Tesla Digest, Vol 59, Issue 13
Hi Tesla fans,I have two 15KV 60ma NST's.Can these be wired in series to get
30KV or wired in paralell to get 120ma?Newcomer Nathan
Thanks for your suggestions,
Mark
SNIPPPPP>>>>>>>>>>>>>>>>>
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla