Re: [TCML] 50Hz = 'short end of the stick?'
> For example, a line frequency which is lower results in a less-efficient
> transformer (weight:wattage)
Low frequency, if designed for, is higher efficiency in
the transformer. Hence (as noted) the past (and, indeed,
present) use of 25 Hz, 16 2/3, etc in specific applications.
'50/60' rated components may be optimized for one, the other,
or the middle. Need to bench test, or get Really Deep into
the data sheets to be sure.
Other effects, eg 'bang rate', may favour high frequencies.
best
dwp