Hi Gary,
Am I also to assume by your comments that I do not ground the EMI filters for
the NSTs; that there is no reason to even run a ground from the control box to
anything external?
Thanks,
Miles M
________________________________
From: Gary Lau <glau1024@xxxxxxxxx>
To: Tesla Coil Mailing List <tesla@xxxxxxxxxx>
Sent: Sun, July 25, 2010 4:38:55 PM
Subject: Re: [TCML] Tesla Coil Computer Interference (proper grounding)
Concerning the connection of mains and RF grounds -
If you have an NST connected to a Terry filter, the NST case is connected to
the RF ground if you've hooked it up properly. If you also connect the NST
case to the green-wire ground, then you have connected your RF ground to
your green-wire ground. This is wrong and defeats the purpose of having a
dedicated RF ground - to channel RF away from your mains wiring. They must
remain separate.
_______________________________________________