[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [TCML] My NST
In a message dated 6/14/2008 9:12:14 A.M. Central Daylight Time,  
noongoble@xxxxxxxxx writes:
<< I'm somewhat confused as to what the rating is on this  NST.  Can anyone
please decifer these numbers for me?  I couldn't  take a picture of the
panel, so I'll just type what I see. >>
 
 
Hi Nicholas,
 
Label explained below:
The transformer is labeled "Transco" and says  that it was made in Hong Kong
in June of '94. (Before GFCI, so good!)
Hz           60 = 60  Cycle AC input/output
PPI.V.     120 = Primary Voltage In
SEC.V.   9000 = Secondary Voltage  Out (open  circuit)
V.A.         270 = VoltAmp  rating
A.             247 (should be 2.47) = Actual Primary Current in Amps
M.A.        30 = .03 Amps, or 30 mA  Secondary Current (short circuit)
 
 
Tony G
 