Re: [TCML] pole pig ballasting
You're sure it's a 12470V primary? That would be an oddity indeed. I'm guessing the primary voltage on the nameplate probably reads something like "7200 / 12470Y". The "12470Y" part is largely irrelevant; this would be a 7200V transformer. The "Y" voltage on pole transformers is a common source of confusion.
Cheers,
Aaron, N7OE
--- On Thu, 7/17/08, garry neeley <bamacoiler@xxxxxxxxx> wrote:
> From: garry neeley <bamacoiler@xxxxxxxxx>
> Subject: Re: [TCML] pole pig ballasting
> To: "Tesla Coil Mailing List" <tesla@xxxxxxxxxx>
> Date: Thursday, July 17, 2008, 10:29 AM
> That's awesome. I wasn't aware of any other coiler
> beside David Rieben up
> in TN this close. BTW Philip where do you work at?
> I'm a calibration
> technician and work at Wyle Laboratories in Madison. I
> would have loved to
> make the trip to see the green monster. BTW David I
> didn't even open the
> link to your coil because I've been drooling at it for
> a couple years now.
> I've known of you for at least that long. I'm a
> pretty quiet forum
> person.(actually I haven't been following the list for
> awhile lately. David
> my pig is 277in 12470 out 50kva industrial unit. I saved
> iit from the
> scrapyard when they replaced 3 pigs recently her at Wyle.It
> would be a
> pleasure to get together with you guys sometime. I
> don't have an actual
> working coil at the moment but am in the planning (and
> aquiring)stage for my
> pig powered coil atm.