[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TCML] dry cap voltages and corona





No, this is the pulse DC design rating.

Using a 14.4 kV xmfr, set your design for 60 kV DC pulse duty max. So, design the cap to handle 60 kV DC to run with a 14.4 kV or 12 kV nst. We design our commercial units for 80 kV DC and run them in air in a polystyrene box.

Dr. Resonance

Resonance Research Corp.
www.resonanceresearch.com


----- Original Message ----- From: "david baehr" <dfb25@xxxxxxxxxxx>
To: "Tesla Coil Mailing List" <tesla@xxxxxxxxxx>
Sent: Sunday, November 18, 2007 6:37 PM
Subject: RE: [TCML] dry cap voltages and corona



So, at 250v/mill DC,...that would be about half of that in Tesla service ?, (125v)
From: resonance@xxxxxxxxxxxx> To: tesla@xxxxxxxxxx> Subject: Re: [TCML] dry cap voltages and corona> Date: Sun, 18 Nov 2007 14:45:53 -0700> CC: > > > > In air, keep your design Volts/mil to around 250 V/mil (DC values) and you > will have no problems.> > Dr. Resonance> > Resonance Research Corp.> www.resonanceresearch.com> >
_________________________________________________________________
Connect and share in new ways with Windows Live.
http://www.windowslive.com/connect.html?ocid=TXT_TAGLM_Wave2_newways_112007_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla


_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla