Original poster: "P.Sarkar" <P.Sarkar@xxxxxxxxxxx>
Hello
I have a Tesla transformer with a single turn primary wound on a cylindrical
former and the secondary turns (30 turns) are wound on conical former, with
the high voltage end being at the smaller radius of the cone. The secondary
winding is inside primary winding.
I want to calculate the inter-turn capacitance of the secondary windings, or
the capacitance between any two turn on the secondary. Is there any formulae
for such case, please help me.
Regards
Partha