High Power SRSGs



Original poster: "Gerry  Reynolds" <gerryreynolds@xxxxxxxxxxxxx>

Hi All,

The SRSG I built for my NST farm (15KV 120ma) has two static and 4 flying electrodes and arcs thru two gaps. The 8 inch diameter disc runs at 1800rpm (120pps) and the four flying electrodes are all electrically connected together and rotate on a 6.5 inch diameter circle . I have noticed that at the 2KW level, I might be seeing the beginnings of power arcing.

Question: for higher power levels it is certainly beneficial to go to a larger disc, but is it also beneficial to have four stationary electrodes and arc thru 4 gaps??

Gerry R.