[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
RE: Yokogawa Power Primer
Original poster: Sparktron01@xxxxxxxxxxx
Hi Dan,
-------------- Original message ----------------------
From: "Tesla list" <tesla@xxxxxxxxxx>
> Original poster: <dhmccauley@xxxxxxxxxxxxxxxxxxxxxxxxxx>
>
> Dave,
>
> I have used a PZ4000 Power Analyzer to do some measurements on my DRSSTC
> systems, however, it was quite susceptible to radiated noise from the DRSSTC
> and frequently locked up and rebooted at times. Not sure how other units
> would react under similar circumstances . . .
>
> Dan
> ---------------------------------------------------------------
Not sure the cause of the lockups. PZ4000 has a higher bandwidth
(10Mhz if memory is right), 12 bit A/D and is more akin to a
"bandwidth limited" digitizing oscilloscope. I assume shielded
cable(s) were used for input lines?
Only failure we ever had with Yokogawa equipment was a "HARD" failure
(no displays, "lights out-nobody's home" scenario). Which is good for
preventing taking questionable measurements in a production environment.
>
>
> Best Regards
> Dave Sharpe, TCBOR/HEAS
> Chesterfield, VA. USA
>
>