[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
RE: Contactor Question - Order In Circuit
- To: tesla@xxxxxxxxxx
- Subject: RE: Contactor Question - Order In Circuit
- From: "Tesla list" <tesla@xxxxxxxxxx>
- Date: Mon, 22 Aug 2005 17:38:32 -0600
- Delivered-to: testla@pupman.com
- Delivered-to: tesla@pupman.com
- Old-return-path: <vardin@twfpowerelectronics.com>
- Resent-date: Mon, 22 Aug 2005 17:41:57 -0600 (MDT)
- Resent-from: tesla@xxxxxxxxxx
- Resent-message-id: <8eijMD.A.k9.ELmCDB@poodle>
- Resent-sender: tesla-request@xxxxxxxxxx
Original poster: "Cameron B. Prince" <cplists@xxxxxxxxxx>
Hi Paul,
Thanks for your feedback. This was how I was planning to connect mine as
well. I have a 60A breaker in my control panel before the variac. Have you
had any issues with the contacts welding shut?
Thanks,
Cameron
> -----Original Message-----
> From: Tesla list [mailto:tesla@xxxxxxxxxx]
> Sent: Monday, August 22, 2005 12:44 PM
> To: tesla@xxxxxxxxxx
> Subject: Re: Contactor Question - Order In Circuit
>
> Original poster: "Paul Benham" <paulb@xxxxxxxxxxxxxxxxxxxx>
>
> Hi Cameron,
>
> I used to have the contactor before the variac. When I
> upgraded to a 45A variac the inrush current caused problems,
> even with inrush current limiters fitted. It is now wired so
> the contactor is after the variac. I have a double pole
> isolation switch before the variac. It is handy being able
> to measure the output voltage from the variac before
> energizing the coil.
>
> Cheers,
>
> Paul.
>
> ----- Original Message -----
> From: "Tesla list" <tesla@xxxxxxxxxx>
> To: <tesla@xxxxxxxxxx>
> Sent: Saturday, August 20, 2005 7:47 PM
> Subject: RE: Contactor Question - Order In Circuit
>
>
> > Original poster: "Cameron B. Prince" <cplists@xxxxxxxxxx>
> > > Hey guys, > > Do you suggest the contactor to be
> before the variac on the line side or > after it on the
> output side? One of the primary reasons David is using one >
> is to get the surge required to break the multiple spark
> gaps. From what I > understand, some of the time when he's
> just running up the variac, it's not > firing them. So if he
> started at 0V to protect the contacts, it would defeat > the
> purpose of the contactor anyway.
> >
> > I am in the process of adding a contactor to my controller
> and was planning > to put it on the output side. This way I
> could use the voltmeter to set the > variac where it should
> be, get the ARSG up to speed then fire the contactor >
> sending the power out to the pig. I plan to have a key switch
> and a dead > man's switch in series with the contactor coil.
> >
> > Are there advantages and disadvantages either way? What do
> you suggest?
> >
> > Thanks,
> > Cameron
>
>