[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: some new ideas for the SSTC guys
Original poster: "Kreso Bukvic" <kreso.bukvic-at-kc.htnet.hr>
Well im going to be stupid again :-).
But what is a hiatus?
Best Regards
Kreso Bukvic
----- Original Message -----
From: "Tesla list" <tesla-at-pupman-dot-com>
To: <tesla-at-pupman-dot-com>
Sent: Monday, October 04, 2004 6:47 AM
Subject: RE: some new ideas for the SSTC guys
> Original poster: "McCauley, Daniel H" <daniel.h.mccauley-at-lmco-dot-com>
>
>
> Very interesting. Thanks for posting the idea.
> I am in the process of taking a hiatus in tesla coiling for
> at least six months now so I won't really have time to test your idea.
> But i'm sure
> maybe Steve or Jimmy would try it.
>
> Dan
>
>
>
> >Problem --- Exploding IGBTs when they are hit with a sec - pri
> >spark (Terry
> >Blake's coil terrible demise at our Teslathon).
> >
> >A few years ago I did some experiments with a flat spiral coil
> >(18 dia.
> >sec.). In the classic configuration with a .05 uF cap, RSG,
> >and 4.5 turn
> >primary the sec sprayed out 8 ft long sparks.
> >
> >At the urging of a plasma physics guru from UW-Madison (Paul
> >Nonn for those
> >of you who might remember meeting him at Ed's recent
> >Teslathon), I removed
> >the sec coil and placed it on a stand 10 feet away. I used a
> >7 inch corona
> >ball on the bottom to prevent any corona and used a single tap which I
> >attached to the "normal" primary coil. With some re-tuning it
> >was again
> >spraying out 8 ft sparks.
> >
> >What I'm getting at here, is, the SSTC experimenters, Dan M.,
> >Steve W.,
> >etc, might try using a larger dia sec coil and then use a
> >15-20 turn test
> >primary coil while feeding the sec coil a few feet away. If
> >this works,
> >then the greatest danger to SSTCing, ie, blowing the IGBTs
> >should become a
> >problem of the past.
> >
> >It will take some experimenting --- perhaps the best tap is
> >"inside" the
> >normal classic tap location or perhaps it will be "outside",
> >but either
> >way, getting the sec away from the primary to act as a series
> >fed setup
> >should eliminate the IGBT explosion problem. If it does work
> >the primary
> >can be either a flat spiral or normal solenoid coil ---
> >perhaps enclosed in
> >clear acrylic with a large "feeder" wire over to the sec coil.
> >
> >If someone DRSSTC tinkering wants to experiment with this idea
> >on their
> >present or planned near future coil, please advise and I will
> >send you a
> >nice 10 ft long chunk of #6 AWG for experiments --- with 125 kV BIL
> >insulation --- it's 1 inch thick and offers great HV feedwire
> >performance. We use this "big Red" on all our HV power
> >supplies to feed
> >the 14.4 kV HV over to the base of the oscillator.
> >
> >Might work, might not, but worth trying.
> >
> >Dr. Resonance
> >
> >
> >
> >
>
>
>
>