[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: MOT leakage
Original poster: "Finn Hammer" <f-h-at-c.dk>
All,
Provided that the primary windings are situated at the bottom of the Elams,
another possible advantage may be harvested:
Having the secondary windings positioned between 2 primary windings may
reduce the leakage inductance to plate transformer levels, making the
creation of a stiff supply a possibility.
Based on speculation, not experiment.
Cheers, Finn Hammer
Tesla list wrote:
>Original poster: "Steve Conner" <steve.conner-at-optosci-dot-com>
> >Why not interconnect the windings as you have suggested, but leave the
> >transformers intact and separated?
>
>That might well work, but then again they may not share voltage equally, so
>one might saturate while the other hardly pulls its weight. Combining the
>two cores into one forces the same flux in each set of coils and hence the
>same voltage.
>
>With the two separate transformers, connecting the filament windings
>together might make them balance better.
>
>Steve C.
>
>
>