[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: CD 942 failure - Found it!!
Original poster: "Virtualgod" <mike.marcum-at-zoomtown-dot-com>
Smaller than usual primary inductance woiuld be my first guess or tighter
than usual coupling perhaps?
----- Original Message -----
From: "Tesla list" <tesla-at-pupman-dot-com>
To: "John Richardson" <jprich-at-up-dot-net>; <tesla-at-pupman-dot-com>
Sent: Monday, March 08, 2004 8:08 PM
Subject: CD 942 failure - Found it!!
> Original poster: Terry Fritz <teslalist-at-twfpowerelectronics-dot-com>
>
> Hi John and All,
>
> It's a peak current failure.
>
> Our new failure mode...
>
> Although the CD942 caps have solid metal plates that never blow
> out. Apparently, the floating metalized layer can.
>
> http://hot-streamer-dot-com/temp/JohnRcap.jpg
>
> http://hot-streamer-dot-com/temp/JohnRcap2.jpg
>
> The entire area between the electrodes has bad current stress failure
areas
> much like a fuse. About 1/4 of it is blown clear. There does not seem to
> be any RMS heat melting, but the peak currents probably are twice what the
> cap is rated at:
>
> http://www.cornell-dubilier-dot-com/film/9422000.htm
>
> maybe 860 amps per cap or a total of 2600Amps peak in the four
> strings!! John mentions that the primary and such get very hot!! What I
> don't know is why the high currents? People use one string with 12/30,
two
> with 12/60 without trouble. So it would seem John's coil is drawing
> unusual very high peak currents. But I don't know why.
>
> Cheers,
>
> Terry
>
>
>