[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Bleed resistors for MMC caps
Original poster: "Jim Mitchell" <Electrontube-at-sbcglobal-dot-net>
The point he's trying to make is that the MMC cap is directly in parallel
with the transformer secondary, which is a big resistor when it is off, so
the relay would have no effect.
Regards - Jim Mitchell
----- Original Message -----
From: "Tesla list" <tesla-at-pupman-dot-com>
To: <tesla-at-pupman-dot-com>
Sent: Tuesday, June 08, 2004 10:28 PM
Subject: Re: Bleed resistors for MMC caps
> Original poster: Tom Wideman <twidem01-at-baker.edu>
>
> What if the relay were powered by an independant DC power
> source?
>
> ---- Original message ----
> >Date: Tue, 08 Jun 2004 08:36:13 -0600
> >From: "Tesla list" <tesla-at-pupman-dot-com>
> >Subject: Re: Bleed resistors for MMC caps
> >To: tesla-at-pupman-dot-com
> >
> >Original poster: "Mark Broker" <mbroker-at-thegeekgroup-dot-org>
> >
> >Each capacitor needs its own bleeder resistor. Placing one
> large resistor
> >across the MMC could lead to a condition in which
> capacitors in a string
> >could be individually charged but yet maintains a net
> charge of zero. I'm
> >not certain what conditions these are, but I still think
> it's a very good
> >idea to use individual bleeder resistors.
> >
> >The transformer will actually short the entire capacitor
> when the power is
> >removed anyway, so your relay wouldn't have much effect.
> >
> >Mark Broke
> >Chief Engineer, The Geek Group
> >
> >
> >On Mon, 07 Jun 2004 18:27:59 -0600, Tesla list
> <tesla-at-pupman-dot-com> wrote:
> >
> >>Original poster: Tom Wideman <twidem01-at-baker.edu>
> >>
> >>Instead of using some sort of bleed resistor....could you
> >>use a normaly closed contact off a solid relay? So that
> >>when the circuit is off the relay redirects all gathered
> >>electrons to ground? Just a thought....tell me what you
> >>think.
> >>
> >>-Nano2e
> >
> >
> >
>
>