[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: Wiring MOTs



Original poster: "Hydrogen18" <hydrogen18-at-hydrogen18-dot-com> 





 > Original poster: "Aaron Aab" <striker754-at-earthlink-dot-net>
 >
 > Im putting 4 MOTs in series with the center 2 secondaries one connected to
 > ground.

You dont really make any sense there. Maybe you are saying that you want to
arrange the transformers in 5000-0-5000 so the HV windings only see double
the voltage and not quadruple. I shoudl make a diagram for this.....
 >
 > Do I connect all the cores to ground?
 >
See above.
 > Also, how do i wire up a MOT to use as a ballast?
 >
Wire it in series with whatever you wish to limit the current to. Short the
secondary or add a resistive load to it to control the amount of current
flowing in the primary winding.

http://www.gomedia.ca/~aaawelder/reactor.html

may also be of interest.
 > Aaron
 >
 >