[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: Safety gap taking over



Original poster: "harry" <harry-at-prcn-dot-org> 

I had a similar problem with my 4x15\30 power supply turned out one leg of
one transformer was bad and caused the safety gap to fire continuously,I am
currently running 3x15\30 with safety set at .25" per side for a .5" total
and the safety no longer fires.

Also did you phase the transformers so they don't fight each other ?