[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Arctronics capacitors
Original poster: "Dr. Resonance" <resonance-at-jvlnet-dot-com>
With NST's never exceed 240 mils (0.240) max. Use 120-130 mils max for
initial tuning.
Be sure to use a "Terry filter" between your spark gap and the NST. Never
run the cap in parallel with the input. Always run the spark gap in
parallel with the input and the cap in series with the primary adjustable
tap.
Dr. Resonance
Resonance Research Corporation
E11870 Shadylane Rd.
Baraboo WI 53913
>
> I've ran them at 12kv/90ma for 5 min runs. If it was resonant, probably
had
> the gap too wide. Speaking of which, what would be a good spacing for a
> needle (just 2 wires) safety gap to "milk it for all it's worth" without
> blowing it up?
>