[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: NST isolation level
Original poster: dhmccauley-at-spacecatlighting-dot-com
I have a franceformer 15kV/60mA transformer. With a high voltage adjustable
electronic load we have a work, I've gotten about 65mA at 15kV before the
NST current limits.
Dan
> Hi all,
>
> I've done some tests with a 15/60 NST using a water resistor.
> I was never able to get 15Kv at 60 ma. Max current, about 50 ma or so,
was
> reached at about 8Kv. Raising the resistance from that point lowered the
> current and raised the voltage. Lowering the resistance from that point
> lowered the voltage and raised the current only slightly.
>
> I don't remember the exact numbers but as someone already mentioned the
NST
> seems to work best at about half it's rated voltage. "Best" being max
> current AND voltage at that point.
>
> Rick W.
> Salt Lake
>
>
>
>
>