Finn,

Yes, still no schottky diodes. Now that I have a current probe I will be
taking some definitive measurements as soon as possible. As the moment,
however, I am in the process of moving so it might be awhile.

-Aron


Aron Koscho
KC5UTO
www.hvguy-dot-com
aron-at-hvguy-dot-com



-----Original Message-----
From: Tesla list [mailto:tesla-at-pupman-dot-com]
Sent: Tuesday, September 30, 2003 4:45 PM
To: tesla-at-pupman-dot-com
Subject: Re: Bulk Order 15kW SSTC Boards - Heat sinks Room Temperature


Original poster: Finn Hammer <f-h-at-c.dk>

Aron,

Cool.

Are you still runing at this power level without the schottky diodes inline
of the FET`s?

Cheers, Finn Hammer

Tesla list wrote:
 >Original poster: "Aron Koscho" <kc5uto-at-wt-dot-net>
 >  >I wonder if it would be in order to hard-wire the bridge part of the
 >  >circuit, and confine the control circuit to the PCB.
 >This is what I have resorted to when running 10Kw with my setup. The logic
 >is on a double sided PCB located as close as possible to the bridge. The
 >bridge of IXFN80N50's is wired with .5" x .125" copper buss bar and 8ga
wire
 >to the primary and line. So far this has proven very reliable. Also, the
 >bridge is currently water cooled using an old water cooled heat sink pulled
 >from a CO2 laser switcher. With a flow rate of about 4GPM everything runs
 >cold at 10Kw.
 >-Aron
 >
 >Aron Koscho
 >KC5UTO
 >www.hvguy-dot-com
 >aron-at-hvguy-dot-com