[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Variac Help
Original poster: "Emmett Secrest" <secrest2032-at-msn-dot-com>
<?xml:namespace prefix="v" /><?xml:namespace prefix="o" />
Yes I will be using the Variac between the wall outlet and the NST. I also
intend to use the boost function for the 140V output. At present It will
only be a 720VA system but once I locate a second NST it will be 1440VA. I
am not sure of the current draw but felt a 3.5 A variac thet I had
orginally would be to small. Thanks to all for the advice and help.
Emmett
----- Original Message -----
From: <mailto:tesla-at-pupman-dot-com>Tesla list
To: <mailto:tesla-at-pupman-dot-com>tesla-at-pupman-dot-com
Sent: Saturday, November 22, 2003 10:56 PM
Subject: RE: Variac Help
Original poster: "Lau, Gary" <<mailto:gary.lau-at-hp-dot-com>gary.lau-at-hp-dot-com>
I was about to reply with "No, a dimmer just won't work with an NST".
This question has been asked often on this List and that's the usual
response. But since I happened to have a dimmer and had never
personally tried it, I thought I would.
I was surprised to find that it did work - mostly. It did occasionally
stop, and I had to turn the dimmer down to zero and then it would behave
nicely again. I did notice that when the dimmer was full-on, that
performance would improve somewhat by shorting the leads, so 100% is
more like 90%. And of course, there's no way to achieve the extra 20V
boost that a real Variac can provide, with a dimmer.
But, if the intended application draws anywhere near the 30A that the
original poster's Variac is rated, the $8 dimmer will fry before you can
say "what was that?"
Gary Lau
MA, USA
Original poster: "Philip Brinkman"
<<mailto:peeceebee-at-mindspring-dot-com>peeceebee-at-mindspring-dot-com>
Well, are you putting that variac between the wall outlet and a neon
sign
transformer? If so, you don't need it. Go to walmart and get an $ 8.00
lamp
dimmer with attaced cord, mine works fine on a 15000 volt 30 ma
transformer, it even has a RF filter in it.
> [Original Message]
> From: Tesla list <<mailto:tesla-at-pupman-dot-com>tesla-at-pupman-dot-com>
> To: <<mailto:tesla-at-pupman-dot-com>tesla-at-pupman-dot-com>
> Date: 11/20/2003 10:00:10 AM
> Subject: Variac Help
>
> Original poster: "EMMETT SECREST"
<<mailto:secrest2032-at-msn-dot-com>secrest2032-at-msn-dot-com>
>
> I am in need of help on wiring of a Technipower 30A Variac. I
purchased
it
> used and there are no instructions. I don't want to toast it as it
was a
> little on the expensive side so your assistance is appreciated. It
has
> five connection points in this order;
>
> 1 5 3 2 4
>
> 1 = one end of the coil
> 5 = between connection 1 and the center tap
> 3 = center point of coil
> 2 = between the center point and the end of the coil, point 5
> 5 = the other end of the coil
>
> This is a 130 volt single phase model that mounts inside a cabinet of
some
> type and does not have it's own enclosure.. My question is which
points
> does the 120V supply connect to and which points are the output. Also
where
> would the safety ground connect.
>
> Thanks in advance for your help,
>
> Emmett
>
> _
>