[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: First Light for 10" Coil.
Original poster: "Dr. Resonance" <resonance-at-jvlnet-dot-com>
John:
I think it's simple physics. The top closed turns of the coil act to shield
the electrostatic field from the underside of the toroid. This will cause a
10-20% reduction in the toroid's measured isotropic value.
D.C. Cox
Dr. Resonance
Resonance Research Corporation
E11870 Shadylane Rd.
Baraboo WI 53913
> toroid capacitance when placed on the TC secondary. This capacitance is
much
> less than the toroid capacitance calculated by the standard equations.
Why??
>
> For example with your coil the 12"x42.5" toroid capacitance using the
> standard toroid equations is about 47.4 pf. This will not agree with the
> actual toroid capacitance when it is located on the secondary. The actual
> toroid capacitance is 34 pf which gives the 84.8 KHz (you measured). The
> only way to find this actual toroid capacitance when it is on the
secondary
> is by measuring the operating frequency with and without the toroid after
> the coil is built. You then calculate the resonant frequencies with and
> without the toroid. All of the surrounding conditions that affect the
toroid
> and secondary capacitances will then be accounted for.
>