[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: Texas version of the Arizona OK corral shootout, ie, the Clanton's may have a secret they don't even know about



Original poster: "Scott Hanson by way of Terry Fritz <teslalist-at-qwest-dot-net>" <huil888-at-surfside-dot-net>

"Unless you use a scope across the input to see the "peak" power levels
...... "

Dr. R -

Can you describe the EXACT test setup that was used to enable you to see the
40-50 KVA spikes? What instrumentation was used, how was it connected, and
what steps were taken to ensure that the test setup was not picking up RFI
or EMI from the operating Tesla coil?

Regards,
Scott Hanson

  ---- Original Message -----
From: "Tesla list" <tesla-at-pupman-dot-com>
To: <tesla-at-pupman-dot-com>
Sent: Sunday, April 06, 2003 8:42 PM
Subject: Texas version of the Arizona OK corral shootout, ie, the Clanton's
may have a secret they don't even know about


 > Original poster: "Dr. Resonance by way of Terry Fritz
<teslalist-at-qwest-dot-net>" <resonance-at-jvlnet-dot-com>
 >
 >
 > If you are using a pole xmfr with external reactor you need to realize
that
 > the pole xmfr, on very short pulsed cycles, will draw as much as 50 kVA
for
 > very short current spikes.  These are not evident unless you use a storage
 > scope connected across the primary side.  The short high power spikes
occur
 > just as the reactor tries to saturate.  A standard 10 kva pole xmfr may
 > operate at short pulses of 40-50 kVA when used with a standard
non-saturable
 > reactor design.

(snip)
 >
 >  > Dr. Resonance
 >