Re: Update: Hurray! 6 Pack MOT supply success



Original poster: "Tim J by way of Terry Fritz <twftesla-at-qwest-dot-net>" <digital_raven45-at-hotmail-dot-com>

with my 6 pack supply, I went for a tank capacitance of 160nF to start. With 
9.3 kVA input power my secondary sparks were 12-13ft. I changed to an ARSG 
(10,000-11,000 RPM) and put in a 185nF tank cap. The sparks were 14.2 ft! 
Topload was a mid sized toriod. 12" dia 4" high

With my 4 pack + 190 nF tank cap, I get a absolute max of 12 ft....usually 
the sparks sit at 10-11ft with 6.1kVA input. Still, it is quite fun.