In a message dated 3/19/02 10:30:05 AM Eastern Standard Time, tesla-at-pupman-dot-com
writes:
>
> Matt,
>
> You may need to use about a 60uF cap or so. The key is to
> measure the voltage across the motor, while rotating the variac
> knob. The voltage should rise about 3 to 5 volts over line voltage
> at some point along the variac range. Also, the motor should
> remain locked for the full variac range or close to it. Only
> trial and error will determine the correct cap size.
>
> Cheers,
> John
Thanks John,
I needed that order of magnitude clue as I did not know if 15uF was
too large or too small for 1/7 hp. Since I have a box of 15uFs I can stack and
rack in series and parallel, until I hit the right combo.
Matt D.