[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Structrual support, was: oil dielectric



Original poster: "by way of Terry Fritz <twftesla-at-qwest-dot-net>" <Xyme3-at-aol-dot-com>

In a message dated 05/18/2002 10:15:29 PM Pacific Daylight Time,
tesla-at-pupman-dot-com writes:


>
> >
>
>
>
> > On a slightly different subject:
>
>
> > If the inside pipe were stainless steel, covered with
>
> > ceramic both inside and out, do you think it would present
>
> > a problem with the action of the coil?
>
>
>     I'd expect it to not work.
>
>
> > (PS, non-magnetic stainless)
>
>
>     The mag fields would excite eddy currents in the
>     stainless, (due to conductivity, rather than magnetic
>     (or nonmagnetic)) leading to huge losses and heating.
>
>     If secondary form, It would arc over, in addition.
>
>     Unless I'm misunderstanding...
>
>     best
>     dwp



No, and i think you are absolutely correct. I had not thought about losses in
the form of heating, i was merely thinking of structrual support. Would there
be a problem with ceramic coated PVC? 
Paul