Re: MMC Construction
Original poster: "Sean Taylor by way of Terry Fritz <twftesla-at-qwest-dot-net>" <taylorss-at-rose-hulman.edu>
4 caps in series will only yield 6400 volts handling, not nearly
enough for a 9 kv tranny. The caps should, at an absolute minimum be
rated for 12.6 kV, the peak voltage out of the tranny, but higher
voltage is needed for TC service. Generally 2 times the RMS voltage
of your tranny is used, or 18 kV for your 9 kV NST. Hope that makes
sense . . .
Sean Taylor
-------------------
> Original poster: "Shaun R. Phelps by way of Terry Fritz
<twftesla-at-qwest-dot-net>" <shaun-at-visorloop-dot-com>
>
> Hi.
>
> Before I blow my new cap bank up (and possibly myself too), I wonder
if someone
> could confirm with me that I am doing this right.
>
> I have a 9KV 60mA transformer. I have purchased 25 - 1600V 12nF
poly-pulse
> capacitors. I figure the best solution here is to have 6 parallel
rows of 4
> caps in series, thus achieving 0.018uF, which is close enough to my
0.0177uF
> requirement. I'm just hoping that these will suffice for the 9KV
voltage in.
>
> Thanks.
>
> Shaun.
>
>
>
>