Re: help..blown nst



Original poster: "Terry Fritz" <twftesla-at-qwest-dot-net>

Hi,

If you had properly set safety gaps that should do most of the protection.
If the NSTs were used, then they could have been about gone already.  It
sounds like the tar has shorted which is usually do to too much voltage or
dry cracked tar failing.  If you can still ohm resistance from the dead leg
to ground, the wire is good and maybe just reheating the tar will cure the
short.

Cheers,

	Terry


At 03:20 AM 1/22/2002 +0000, you wrote:
>i think i have just blown my second nst.what am i doing 
>wrong,i stopped using the rotary gap and put in a safety 
>gap ...from each pole of the nsts to ground,i am 
>thinking now that it is a bad thing to use one common 
>ground {input sec and safety all grounded together}?one 
>nst is ok the other 15000 60ma,good arc to pole from 
>ether side one side good arc to ground the other no arc 
>to ground.i have not depotted one yet but i dont think 
>that will be a prob but i dont know how to go about 
>repairing once i get it depotted....thanks alot for all 
>your help
>