Re: On going pig ground dispute



Original poster: "by way of Terry Fritz <twftesla-at-qwest-dot-net>" <Tesla729-at-cs-dot-com>

In a message dated 2/9/02 8:58:23 AM Pacific Standard Time, tesla-at-pupman-dot-com 
writes:

<< Hello esteemed Ed and all of the list,
 
 My pig has a heavy copper strap going to pig ground from the neutral
 lug. Do you choke both sides of your pig? Otherwise, wouldn't the
 grounded leg of the pig receive full power if using an inductive balast
 on one side of the center tapped 240V, or am I missing something here?
 Jim >>

Hi Jim,

You must remove the copper strap ground from the center tap of the LV
side of the pig to the case ground, if your pig is equipped with one of 
these. Otherwise your observation would indeed be correct. The center
tapped LV lug is left floating while the 240 volt input is tied into the two
outer LV lugs. Hope this helps.

David Rieben