[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: a/c switches and Control Box Enclosures



Original poster: "Daniel McCauley by way of Terry Fritz <twftesla-at-qwest-dot-net>" <dhmccauley-at-spacecatlighting-dot-com>



I'm still working on the schematic, so it should be up by a day or two at:

www.spacecatlighting-dot-com

Dan



> Hi,
> I'm sure some of us would like to see the schematic for this, If you have
it.
>
> Thanks,
> ---------------------------------------
> Jonathon Reinhart
> hot-streamer-dot-com/jonathon
>
> >
> > I use the same box.  Here is a picture of my box.  It features the
> > following:
> >
> > http://www.spacecatlighting-dot-com/ctc1_ctrlbox01.jpg
> >
> > - 5A Circuit Breaker (used as switch as well) for my Synchronous Rotary
> > Spark Gap
> > - 15A Circuit Breaker to power my NST Mains
> > - Key Lock Safety Circuit (prevents unauthorize use)
> > - 40A 240VAC Latch Relay Circuit
> > - Logic to prevent NST Mains power to be energized unless SRSG is
running.
> > Actually, the NST Mains power will not be
> >    able to be enabled unless the circuit breaker for the SRSG is in the
"ON"
> > position.  This is just a little extra back-up so one doesn't power up
the
> > NST Mains and blow the cap, but the safety gaps on the NST filter and
the
> > SRSG assembly should also prevent damage.
> >
> > -Psycho Dan
>
>
>
>
>
>