[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Step up transformer earth
Original poster: "Jason Petrou by way of Terry Fritz <twftesla-at-qwest-dot-net>" <jasonp-at-btinternet-dot-com>
Paul,
I connect the HV centre tap of my neon to RF ground, and I would do the same
for the MOT system. The reason for this is that I use a filter network and
if the potential across the 2 grounds was different then the caps on the
network may well be overrated.
Best regards,
Jason
----- Original Message -----
From: "Tesla list" <tesla-at-pupman-dot-com>
To: <tesla-at-pupman-dot-com>
Sent: Monday, November 26, 2001 3:23 PM
Subject: Step up transformer earth
> Original poster: "Paul Arrowsmith by way of Terry Fritz
<twftesla-at-qwest-dot-net>" <p_t_arrowsmith-at-hotmail-dot-com>
>
> I am powering a coil with a NST that has the center tap (case) connected
to
> mains earth. On my other coil I am using 4 X MOT,s with the secondarys in
> series, where the two inner transformers join is also connected to the
house
> wiring earth. Should I be connecting these points to my dedicated RF/Tesla
> earth instead? I have never experienced a problem with grounding this way
> but want to ensure that my grounding is safe.
> Paul A.
>
> _________________________________________________________________
> Get your FREE download of MSN Explorer at http://explorer.msn-dot-com/intl.asp
>
>
>