Waaaaait a min.

both caps need to only be 1/2 the req voltage, but x2 capacitance??

Theoretically, you could run a 6kv 1.0 mu-f cap on each HV line and not be 
under the req cap voltage rating with a 9kv 30ma nst??

How does that work, exactly...

Thanks
Erik



Gary,

I agree.  Richard Quick Is the only coiler that I know of that built an
equidrive coil system.  I believe he used two .10 ufd caps.  His system
worked very well, I have video of it running.  Twelve to fourteen foot arcs
if I remember correctly.  He liked the set up.  I have not seen evidence of
increased performance with this system over the single cap design.  The
equidrive caps only need half the voltage rating but need to be twice the
capacitance.  You also must remember to discharge the caps after every run 
as
the transformer secondary windings will not provide that function as it does
with a single cap.

Ed Sonderman




_________________________________________________________________
Get your FREE download of MSN Explorer at http://explorer.msn-dot-com