Re: Dimmer as a Variac.
Original poster: "David Sharpe by way of Terry Fritz <twftesla-at-qwest-dot-net>" <sccr4us-at-erols-dot-com>
Marc
Which makes perfect sense for a SCR controller designed for 480-600VAC.
Typical industry standards (at least in USA)...
Vin VRRM (Voltage Reverse Recovery Max)
120VAC 400V
240VAC 800V
480VAC 1.2kV
600VAC 1.4, 1.5, 1.6, 2.0kV *
*Depends on part availability, class of service, and exposure to severe
electrical transients.
Regards
Dave Sharpe, TCBOR
Chesterfield, VA. USA
Tesla list wrote:
> Original poster: "Metlicka Marc by way of Terry Fritz
<twftesla-at-qwest-dot-net>" <mystuffs-at-orwell-dot-net>
>
> to all from me,
> >i would much like to get some help in breaking this unit down so that i
> >could try to build one that uses the 15kv\400amp scr's that i have. if
> >
>
> ooops, i should correct those scr values, the ones i have are 1.5kv-at-400
> amp.