I just wanted to share the results of my recent MOT tests:
Both xformers have got the same gross-core-volume of 708 cm^3 =
43.2 cubic inch (hopefully). Window-cross-section and other details
were not taken into account.
#1: label: 230 V / 50Hz, 2060 V, 1100 VA
R prim 1.1 Ohms
R sec 102 Ohms
V sec 2107 V
L mag 195 mH
L leak 53 mH
#2: label: 230 V / 50 Hz, 2300 V / 0.7 A, 1350 W
R prim 1.1 Ohms
R sec 93 Ohms
V sec 2079 V
L mag 412 mH
L leak 64 mH
Hoping these data could be useful for simulation and could clarfiy
to what extend MOTs are current limited.
A happy New Year and take care of you!