Re: I Think I Messed up!



Original poster: "by way of Terry Fritz <twftesla-at-qwest-dot-net>" <Mddeming-at-aol-dot-com>

In a message dated 12/3/01 1:50:40 PM Eastern Standard Time, tesla-at-pupman-dot-com
writes:


>
> My primary consists of just under 15 turns of 1/4" copper pipe spaced 1/4"
> apart. My secondary is 4" x 28" wound with 28 guage wire. I just ran QuickTC
> and it indicates the tap point would be turn 18!!! I didn't design for this
> at
> all!
>
> Do I have any recourse?? I really *cannot* scrap my primary and rebuild!
>
> Please give me some words of re-assurance.
>
> Thanks,
> Patrick
>
>


Patrick
A smaller topload would raise the operating frequency and therefore require a
smaller primary for a given size tank cap.
Alternatively, a slightly larger tank cap will allow a smaller primary coil
without changing the operating frequency.
Matt D.