[Prev][Next][Index][Thread]

Re: Best case senario secondary output?




If you are running a non-sync stationary gap with 4-5 gaps and a small
blower fan with a typical sec dia of 4-6 inches, expect approx 18 to 22
inches from a 12 kV 30 mA xmfr.

-----Original Message-----
From: Tesla List <tesla-at-pupman-dot-com>
To: tesla-at-pupman-dot-com <tesla-at-pupman-dot-com>
Date: Wednesday, February 23, 2000 11:32 AM
Subject: Re: Best case senario secondary output?


>Original Poster: FutureT-at-aol-dot-com
>
>In a message dated 00-02-22 19:09:17 EST, you write:
>
><<
>> Original Poster: "Bryan Miller" <ftbll-at-MailAndNews-dot-com>
>
>> While on the subject.  Could someone give me an optimized spark length
>using a
>> 12kV 30mA NST?  Thanks for the help!
>  >>
>
>I get 42" from a 12/30 NST using a sync rotary gap, and a 0.0147uF
>cap.      http://members.aol-dot-com/FutureT/TT-42index.html
>
>Cheers,
>John Freau
>
>
>