Re: Capasitor match
> Original Poster: FutureT-at-aol-dot-com
>
> The matching concept applies only to current limited transformers
> such as NST's and OBIT's. It's best to use a capacitor that is larger
> than the matched size (LTR). This reduces the voltage stresses on
> the NST.
As well as the cap! Running with a resonant cap can kill the cap and the
transformer if you open the gap too wide, or something goes open-circuit on
you.
I too am now an advocate for the LTR cap.
-Adam