[Prev][Next][Index][Thread]
Re: Tesla Coil Operation - was "Harmonics"
Ed -
Are you saying these mechanical analogies represent 4th order differential
equations as shown in the Corum's TCTUTOR book?
John Couture
-------------------------------
At 07:36 PM 1/30/99 -0700, you wrote:
>Original Poster: Ed Phillips <evp-at-pacbell-dot-net>
>
>------------- snip
>
> As for mechanical analogies, these are mechanisms which can be
>described by the same differential equations as the electrical circuits
>for which they are analogs. (Works both ways, of course). The coupled
>pendulums (pendula?) are exact analogs of the Tesla "magnifier", and
>with the correct common mass (pendulums connected via an extra mass, as
>described by Antonio) will exhibit most of the behavior of the normal
>magnetically-coupled TC, including "resonant rise" and "beats" between
>the primary (heavy pendulum) and secondary (light pendulum) motions. The
>latter case is exactly analogous to the circuit where the coupling
>between primary and secondary is through a common inductor (or
>capacitor) at the "bottom" end.
>
>Ed