[Prev][Next][Index][Thread]
Fwd: That secondary harmonic voltage distribution stuff...
-
To: tesla-at-pupman-dot-com
-
Subject: Fwd: That secondary harmonic voltage distribution stuff...
-
From: Terry Fritz <twftesla-at-uswest-dot-net>
-
Date: Wed, 25 Aug 1999 21:48:27 -0600
-
Approved: twftesla-at-uswest-dot-net
-
Delivered-To: fixup-tesla-at-pupman-dot-com-at-fixme
Hi All,
I just took the measurements on my coil without top load. Here are the
numbers...
The graph is at:
users.better-dot-org/tfritz/VoltDistBare.jpg
Pos 1st 2nd 3rd
136.98 341.0 504.1
0 2.12 1.79 1.31
1 3.09 2.54 1.84
2 4.16 3.62 2.55
3 5.38 4.88 3.31
4 6.54 6.15 4.11
5 8.13 7.63 4.85
6 9.72 9.29 5.41
7 11.5 10.8 5.77
8 13.2 12.2 5.94
9 15.2 13.4 5.84
10 17.6 14.3 5.51
11 20.2 15 4.88
12 23.1 15.3 4.02
13 26.3 15.3 3.04
14 30.2 15.1 1.92
15 34.4 14.7 1.04
16 38.8 13.7 1.2
17 44.1 12.6 2.19
18 49.9 11.4 3.16
19 57.3 9.81 4.05
20 64.5 8.27 4.61
21 72 6.54 4.83
22 78.4 4.95 4.81
23 84.6 3.16 4.57
24 90.2 1.7 4.01
25 94.2 0.7 3.24
26 96.9 1.6 2.25
27 99.6 3.06 1.12
28 100 4.3 0.2
29 100 5.43 1.13
30 98.7 6.28 2.01
31 70.7 6.48 2.48
32 70.1 5.61 2.2
These numbers are a "little" more as expected.... That 1st fundamental is