[Prev][Next][Index][Thread]
Re: Rotary Sync Gap
Original Poster: Terry Fritz <terryf-at-verinet-dot-com>
Hi All,
SNIP
I do have one question. Is there a way to hook up a neon lamp, high
brightness LED, etc. to shine on the rotor to indicate were in the ac
cycle the rotor is at. In other words, I am trying to get the gap points
to line up at the peak of the AC cycle. There must be some simple device
to do this. I do have a nice inductive timing light that may be a
possibility too. With my voltage probe down I can't see the cap voltage
directly.
Terry Fritz
Hi Terry,
How about using a timing light from a car ? Hook it up to 12 volts and connect
the magnetic probe to one of the HV leads. You could even make it permanent
using a megnetic pickup and a small trigger/driver circ to run an LED.
Coiler greets from Germany,
Reinhard