[Prev][Next][Index][Thread]
Re: new power transformer
Tesla List wrote:
> Hi All,
>
> For the last 6 months or so I have been running my 3KW magnifier system
> with and output varying from 4-6 feet. The problem is form marathon runs
> my power transformers overheat and start smoking after 30 min. They are
> two 5 KV 300 ma transformers put in series.
> I am ready to upgrade these to a potential transformer or a 5 kva pig.
> My question is are the potential transformers current limited cores? or do
> these also need ballasting to work.
> The reason for leaning more for the potential transformer is that I
> like to keep the system portable and not everywhere I take it has 220
> available to me. Also the pigs tend to be very heavy and hard to put on a
> truck.
> Could anyone give me advise either way.
>
> Thanks,
>
> Dwight Duncan
A lightweight potential Xfrmer might be about 100 lbs. They are never current
limited like a NST and much be ballasted.
Richard Hull, TCBOR