[Prev][Next][Index][Thread]

Magnifier Gen




----------
From:  Malcolm Watts [SMTP:MALCOLM-at-directorate.wnp.ac.nz]
Sent:  Sunday, April 05, 1998 8:19 PM
To:  tesla-at-pupman-dot-com
Subject:  Re: Magnifier Gen

Hi all,
        During a period of terminal measurement over the weekend, I 
finally reconciled this anomaly: 

<snip>
> Resonator: Rdc = 15.5 Ohms
>            Dwire = 0.45mm  (Cu diameter)
>            Pitch = 50TPI
>            Turns = 540 - 550
>            Hwinding = 10.9"
>            Diameter = 3.1"
>           
>            Lcalc = 5.6mH
>            Lmeas = 6.24mH !!  (Sencore L-C Analyser)
> I haven't been able to explain this yet :(
<snip>

I mis-measured the diameter which is in fact about 3.3"+. That gets 
the calculated figure a lot closer to the measured one.