Tesla List wrote:
> 
> From:   Bert Hickman[SMTP:bert.hickman-at-aquila-dot-com]
> Reply To:       bert.hickman-at-aquila-dot-com
> Sent:   Tuesday, September 16, 1997 11:44 PM
> To:     Tesla List
> Subject:        Re: ground problems
> 
> Tesla List wrote:
> >
> > From:   Geoff Schecht[SMTP:geoffs-at-onr-dot-com]
> > Sent:   Tuesday, September 16, 1997 11:38 AM
> > To:     Tesla List
> > Subject:        Re: ground problems
> >
> > > From:         Bert Hickman[SMTP:bert.hickman-at-aquila-dot-com]
> > > Reply To:     bert.hickman-at-aquila-dot-com
> > > Sent:         Tuesday, September 16, 1997 8:12 AM
> > > To:   Tesla List
> > > Subject:      Re: ground problems
> > >
> > > Tesla List wrote:
> > > >
> > > > From:   Mad Coiler[SMTP:tesla_coiler-at-hotmail-dot-com]
> > > > Sent:   Monday, September 15, 1997 6:55 PM
> > > > To:     tesla-at-pupman-dot-com
> > > > Subject:        ground problems
> > > >
> > > > I am back in Columbus for a while and have one problem. I am on the
> > > > second level in an apartment building. Does anyone have any suggestions
> > > > about how I can get a descent ground? I have been using the cold water
> > > > copper pipe to the sink but have been informed that it is a fire risk.
> > I
> > > > suppose I might have to take it to a friends house if that is possible.
> > > > So far I haven't had any noise complaints, but only because I havent
> > run
> > > > it past 8pm.
> > > >
> > > > Mad Coiler
> > >
> > >
> > > Mad,
> > >
> > > Because of the use of plastic plumbing in many areas, your ground may
> > > not really be a ground. To determine if it is, take an ohmmeter and
> > > carefully measure the resistance between the ground connection (the
> > > third prong on a nearby AC outlet) and your cold water copper pipe
> > > ground. If you get good continuity (say 20 ohms or less), then you
> > > should be OK. Another alternative ground is the ironwork of the building
> > > you're in if it happens to be an iron-concrete type structure, or as a
> > > last resort, the AC ground itself if you have a small coil.
> > >
> > > -- Bert --
> > >
> >
> > Hello All:
> >
> > I've used soldered-together sections of "chicken wire" as a form of radial
> > system (counterpoise) for my vertical ham antennas from time to time. It
> > works fairly well in that application and is quite cheap. Any
> > opinions/experience from other list members about how this might work with
> > a TC that needs a grounding system? It's an RF ground, though, not a safety
> > (green-wire, in the US) ground.
> >
> > Geoff (NQ7A)
> 
> Geoff,
> 
> Good point, Geoff. I considered suggesting a counterpoise, but it wasn't
> clear if Mad Coiler's apartment was wood/frame construction or steel
> beam/concrete. A counterpoise could work very well, especially if Mad
> Coiler lived on the first floor. Since Mad Coiler lives on the second
> floor, an elevated counterpoise would still work very well if he was in
> a steel/concrete building, and less so if he lived in a wood/frame
> environment.
> 
>


 -- Bert --But, wouldn't he have to live on the top floor of the world's highest
apartment building for this to be a problem, i.e. an odd-quarter
wavelenth from the earth ground? At the frequencies in question...
Randy
N4MBL