Artificial Line Measurements




From: 	Malcolm Watts[SMTP:MALCOLM-at-directorate.wnp.ac.nz]
Sent: 	Sunday, September 21, 1997 2:55 PM
To: 	tesla-at-pupman-dot-com
Subject: 	Artificial Line Measurements

The Line:

       1.6mH   800uH   400uH   200uH   100uH    50uH    25uH
   -----ooo--+--ooo--+--ooo--+--ooo--+--ooo--+--ooo--+--ooo--+---
             |       |       |       |       |       |       |
            ---     ---     ---     ---     ---     ---     ---
In          ---     ---     ---     ---     ---     ---     ---   Out
             |       |       |       |       |       |       |
   ----------+-------+-------+-------+-------+-------+-------+---
           10pF     22pF    50pF    100pF  220pF    470pF   1nF


Measurements and Calculations:

Vo/Vin = 40V/1.1V (peak volts) = 36.4  (CW drive, Zgen = 7 Ohms)
     Q = 28
  VSWR = 4Q/PI = 35.6
(the above figures include the generator impedance. Subtracting this
from ESR and recalculating gives:
     Q = 32.6
  VSWR = 41.5

Ltot = 3.175mH
Ctot = 1.872nF
F(meas) = 64.9kHz
F(calc) = 65.28kHz  (from sums of lumped components)

ESR(incl. gen) = 46.6 Ohms

Voltage Measurements (nodes are numbered from 1.6mH/800uH junction (1)
                      to Output (7) ).

              (1)     (2)     (3)     (4)     (5)     (6)     (7)
Volts(peak)   19      29.5    35      38      39      39.7     40
Energy(nJ)    1.8     9.6     30.6    72.2    167     370      800

Note: Capacitor and Inductor values are subject to +- 5% maximum error.